ATEX / IECEx

ATEX & IECEx

ATEX is a directive for the use of Ex equipment in the European Union. The IECEx developed by the International Electrotechnical Commission (IEC) is an international cerification accepted in most countries intended to harmonise the standards of Ex equipment.

Interpretation of Zebra L10ax Hazardous Approval

L10-Tablet-ATEX-Eg
*ATEX / IECEx approval from L10 tablet datasheet
Element Rating Explanation
Equipment Group II Used for above surface industries (non-mining)
Protection Category & Atmosphere 3G
3D
Category 3G is the equivalent of Zone 2 (Gas)
Category 3D is the equivalent of Zone 22 (Dust)
This category represents an atmosphere where flammable substances is not likely to occur in normal operations but if it does, will persist for a short period only.
Type of protection ec
tc
Increased safety (for Gas)
Enclosure (for Dust)
Gas Explosion Group
Dust Explosion Group
IIC
IIIB
Most ignitable (ie. Hydrogen, Acetylene)
Most conductive (ie. Metal dust)
Temperature Class T6 T6 certification allows a maximum permissible surface temperature of 85°C therefore a T6 instrument can be used in T5, T4, T3, T2 and T1 environment
Surface Temperature (Dust) T= 85 °C Maximum surface temperature of 85°C with tested dust layer
Equipment Protection Level Gc
Dc
Gc: protection for Zone 2 (Gas)
Dc: protection for Zone 22 (Dust)